Home Products Raised Access Floor Systems Calcium Sulphate Panel

Calcium Sulphate Panel


Unitile Calcium Sulphate access flooring system is manufactured from 1600 Kg/ cubic meter density  fibre reinforced Calcium Sulphate which forms the core of the panel. Non- combustible high quality alpha- hemihydrate single pressed gypsum and non-toxic unbleached cellulose fibers are used as reinforcing material. The base & top surface of the core is factory bonded using an appropriate combination of surface finishes such as Aluminum, Galvanized sheet steel, High Pressure Laminate etc. The edges of the panel are protected with a PVC edge band. The system offer an excellent acoustical sound deadening value.


Gravity Lay System
Substructure in Galvanized Steel
Model Free Standing
Nominal Height mm 100 / 300
Adjustment mm +/-25
Edge Support Rigid Grid System (ESRG)
Substructure in Galvanized Steel with support & stringers for substructure height of over 300mm
Model ESRG
Nominal Height mm 100 / 1000
Adjustment mm +/-25
Structural Performance as per BSEN 12825
Classification Deflection Concentrated Load Kgs/ KN
Class A 2.5 mm 900 / 8.8
Class B 3.0 mm 1000 / 9.8
Class C 4.0 mm 1200 / 11.76
Ultimate Concentrated Load 1500 Kgs / 14.7 KN
Uniformly Distributed Load/ Sq mtr 2900 Kgs/ 28.43 KN
Pedestal Axial Load Test 22 KN (2200 kgs) Axial Load per pedestal
Downloads
Structural Performance as per BSEN 12825
Classification Deflection Concentrated Load Kgs/ KN
Class A 2.5 mm 1000 / 9.8
Class B 3.0 mm 1200 / 11.76
Class C 4.0 mm 1400 / 13.72
Ultimate Concentrated Load 1900 Kgs / 18.62 KN
Uniformly Distributed Load/ Sq mtr 3000 Kgs/ 29.42 KN
Pedestal Axial Load Test 22 KN (2200 kgs) Axial Load per pedestal
Downloads
Access Floor Load Testing
Concentrated Load Uniform Load Ultimate Load Rolling Load Impact Load
These loads are applied on a small area on the panel surface. These loads are applied over the entire surface of the panel. These loads are reached when the panel has failed structurally and can not accept any additional load. These loads are applied by wheeled vehicles arrying loads across the floor. These loads occurs when objects are accidentally dropped on the floor.
Source: “Recommended Test Procedures for Access Floors” published by the Ceiling & Interiors Systems.
Construction Association (CISCA)
These test procedures do not set standards for test results.

Tab content 4

!! This page is Under construction !!
Bare
A raised floor system with bare finish does not have a surface covering. The surface of the panel will normally be steel top sheet which is epoxy powder coated. This bare finished raised floor is covered on site by the application of loose lay carpet tiles.

Applications: General Office
Carpet Shades Available
Isometric Drawings
ESRG FFH Downloads
65-150 mm
150-600 mm
625-750 mm
775-900 mm
925-1000 mm
1025-1500 mm
Section Drawings
ESRG FFH Downloads
65-150 mm
150-600 mm
625-750 mm
775-900 mm
925-1000 mm
1025-1500 mm