LOW FLANGE WIDTH
A Low Flange Width steel cementitious panel provides higher strength and overall stability to the flooring system. Reduced cantilever edges or flange widths reduces the risk of damage during the usage of the system.
Dimensions: 600 mm x 600 mm | 600 mm x 800 mm
Panel Thickness: 30 mm | 35 mm
Top: Flat steel
Bottom: Unique flat steel design with hemispherical pockets
Core: Lightweight proprietary cementitious mixture
Top Finishes: Carpet / HPL / PVC
Application: Open office, Data center, Control room, Casino, Co-working, Education
features
Enhanced load carrying performance
Reduced risk of damage with low cantilever edges
Increased stability with wider beam
Higher footprint area on the pedestal head
Non-combustible
system selection guide
- USF 3000
- 1361 (3000)
- 4536 (10000)
- 7223 (1480)
- 1361 (3000)
- -
- -
-
Corner Lock
Each floor panel is mechanically secured to the pedestal head at all four corners ensuring maximum rigidity and lateral stability. Access to the sub-floor is simply achieved by releasing the fasteners and lifting the panel.
- FINISHED FLOOR HEIGHT:
- Minimum: 65 mm
Maximum: 2000 mm
-
EDGE SUPPORT RIGID GRID SYSTEM
Edge support understructure provides maximum floor stability. It reduces all lateral movements and also ensures integrity of the floor on removal of panels for access to services in the sub-floor. Stringers are mechanically fastened to the pedestal head and panels are then placed on the grid formed. This system is ideal for high finished floor heights.
- FINISHED FLOOR HEIGHT:
- Minimum: 65 mm
Maximum: 2000 mm
-
Drawings
-
certificates
USF 800 30-Uniform load test
DownloadUSF800 30-Concentrated & Ultimate load test
DownloadUSF800 30-Concentrated load test
DownloadUSF 800 30 Rolling Load Test Wheel A
DownloadUSF800 35-Concentrate & Ultimate load test
DownloadUSF800 35-Rolling test
DownloadUSF1000 BARE-UNIFORM LOAD TEST-CISCA
DownloadUSF1000-Concentrate & Ultimate test-CISCA
DownloadUSF1000-ROLLING LOAD TEST WHEEL A-CISCA
DownloadUSF1500-Concentrated & Ultimate load test
DownloadUSF1500-Rolling load test
DownloadUSF1500-Uniform load test
DownloadUSF2000- Rolling load test - Cisca
DownloadUSF2000-Concentrate & Ultimate Load test - Cisca
DownloadUSF2500-Concentrate & Ultimate test-CISCA
DownloadUSF2500-Rolling test-CISCA
DownloadUSF2500-Uniform load test-CISCA
DownloadUSF1250-Concentrate & Ultimate load test-Cisca
DownloadUSF1250-Concentrated load test
DownloadUSF1250-Rolling load test
DownloadUSF1250-Uniform test_MOB PF
Download