U-Flex Power

U-Flex extreme product

The U-Flex Power Structural Ceiling System is an engineered overhead infrastructure solution designed for data centers and critical applications. Built with precision aluminum extrusions and modular connectors, it provides a reliable platform for suspending containment barriers, partitions, and service equipment. With threaded slots for universal compatibility and seismic-ready support, U-Flex Power combines strength, flexibility, and cost-effectiveness for future-ready infrastructure.

Maximum Safe Working Point Load* 4.10 kN
Grid Spacing Options* 600×600 mm, 600×1200 mm, 1200×1200 mm
Standard Finish Mill Finish
Optional Finishes Natural Anodized, Black Anodized, White Partial
Connectors X, L, T, I connectors with zinc electroplated finish
Suspension Components M10 threaded rods, turnbuckles, lock nuts, beam clamps, mechanical anchor fasteners

FEATURES

High Load Capacity

High Load Capacity: Supports up to 4.10 kN point load with robust grid performance.

Universal Compatibility

Versatile Installation: Compatible with both RCC and gypsum structures, supporting rod-drop or perimeter-mounted configurations.

Flexibility

Flexibility & Access: Optional removable ceiling panels allow inspection and maintenance without disturbing supported services.

Precision Design

Threaded Slot System: Continuous threaded slot on both top and bottom for easy attachment of firefighting, power, and ICT utilities.

Multiple Grid Options

Multiple Grid Options: Available in 600×600, 600×1200, and 1200×1200 mm layouts, with customization possible.

Durable Finishes

Durable Components: High-strength, corrosion-resistant connectors and brackets with zinc electroplated finish.

Seismic Ready Design

Seismic-Ready: Integrated design minimizes risks and damage during seismic activity with specialized components.

Sustainable Excellence

Optimized Runner Design: CNC-milled ends and notched runners ensure accuracy, snug fit, and enhanced load strength.

U-Flex Extreme

U-Flex Extreme
Parameters Values
Maximum safe working point load* At Center 250kgs/ 2.45kN
At Suspension 418kgs/ 4.10kN
Maximum safe uniform load* 5.76 kN/ m2/ 586kg/ m2 (1200 x 600 panel)
Required torque for top slot 3.5 Nm
Factor of Safety 2
Top & Bottom slot M10 threaded slots
Technical Specification Doc Download

*All values are indicative — contact us for detailed technical documentation.

FINISH OPTIONS

Natural Anodized

Silver Anodized

Black Anodized

Black Anodized

White Partial

White Partial

Our Certifications

Certification 1
Certification 2
Certification 4
Certification 5
Certification 6